Brand Name: BOGUANG
Origin: Mainland China
Number of Panels: >20
Flexible Solar Panel: No
Foldable Solar Panel: No
Type: Solar Panel
Module Efficien: 24%
Model Number: Solar Panel
Material: Monocrystalline Silicon
Max. Power: 800W /600w / 400w / 300w
is_customized: Yes
Certification: CE
Certification: weeeDescription:
800W 600W 400W 300W Glass Solar Panel Photovoltaic Panel Solar System balcony power plant grid tie inverter for Home Socket 220v 230v Micro Inverter On Grid Solar PV System
Package of list of "800w plug and play"
4* 200w glass solar panel
1* 600W 220V 230V Micro Inverter
1* 5 meters AC cable for socket
2* 3 meters extension cable16* Z brackets
Package of list of "400w plug and play"
2* 200w glass solar panel
1* 300W 220V 230V Micro Inverter
1* 5 meters AC cable for socket
1* 3 meters extension cable8* Z brackets
Output Data(AC)
Single-Phase Grid Type: 120V / 230V
Rated Output Power: 580W
Maximum Output Power: 600W
Rated Output Current: 120V: 2.33A/230V: 1.21A
Rated Output Voltage: 120V AC / 230V AC
Default Output Voltage Range: @120 V AC: 80V-160V / @230V AC: 180V-280V
Rated Output Frequency: 50Hz / 60Hz
Default Output Frequency Range: @50Hz: 47.5Hz-52.5Hz / @60Hz: 57.5Hz-62.5Hz
Power Factor: >0.99
Total Harmonic Distortion: THD <5%Input Data(DC,PV)
Number of Input PV Connector: 1 set
MPPT Voltage Range: 24V-40V
Operation Voltage Range: 18V-50V
Maximum Input Voltage: 50V
Startup Voltage: 18V
Maximum Input Power: 600W
Maximum Input Current: 24ACONNECTION METHOD:
Installation
Step 1- Attaching the micro inverters to the racking.
a.Mark the location of the micro inverter on the rack, with respect to the PV module junction box or any other obstructions.
b. Mount one micro inverter at each of these locations using hardware recommended by your module racking vendor.Step 2- Connect the micro inverter AC cable and connect to AC bus cable (L-brown,N-blue,G- green&yellow) one by one, please do not exceed the maximum current of AC bus cable.
Step 3- Connect micro inverter to the PV module, please do not exceed PV panel(s) VOC over
inverter max. input voltage.Step 4- Install the AC branch circuit junction box, wire the conductors of the AC bus cable. Connect the AC branch circuit junction box to the point of utility-grid Interconnection.
Step 5- Double check all micro inverter, connectors and cables are correctly and well connected.
Step 6- Turn on the AC circuit breaker on each AC branch circuit of micro inverter.
Step 7- Turn on the main AC circuit breaker of utility-grid. Your system will start producing power
after a 30 sec safety delay period.